sigmaDRL-1.1from SigmaHQ/sigma
Silenttrinity Stager Msbuild Activity
Detects a possible remote connections to Silenttrinity c2
Quality
98
FP risk
—
Forks
0
Views
0
ATT&CK techniques
Rule sourcerules/windows/network_connection/net_connection_win_silenttrinity_stager_msbuild_activity.yml
title: Silenttrinity Stager Msbuild Activity
id: 50e54b8d-ad73-43f8-96a1-5191685b17a4
status: test
description: Detects a possible remote connections to Silenttrinity c2
references:
- https://www.blackhillsinfosec.com/my-first-joyride-with-silenttrinity/
author: Kiran kumar s, oscd.community
date: 2020-10-11
modified: 2022-10-05
tags:
- attack.execution
- attack.defense-evasion
- attack.t1127.001
logsource:
category: network_connection
product: windows
detection:
selection:
Image|endswith: '\msbuild.exe'
filter:
DestinationPort:
- 80
- 443
Initiated: 'true'
condition: selection and filter
falsepositives:
- Unknown
level: high